4.3 Controller I/O
AG
AI1
AG
AO0
AG
AO1
AG
AI0
Analog
Analog Outputs
Analog Inputs
24V
0V
PWR
GND
Power
4.3.7 Remote ON/OFF control
Remote ON/OFF control can be used to turn the control box on and off without using
the teach pendant. It is typically used in the following applications:
When the teach pendant is inaccessible.
When a PLC system must have full control.
When several robots must be turned on or off at the same time.
The remote ON/OFF control provides a small auxiliary 12V supply, which is kept
active when the controller box is turned off. The “on” and “off inputs are intended
for short time activation only. The on input works in the same way as the power
button. Always use the “off input for remote off control as this signal allows the
control box safe files and shut down nicely.
The electrical specifications are shown below.
Terminals Parameter Min Typ Max Unit
[12V - GND] Voltage 10 12 13 V
[12V - GND] Current - - 100 mA
[ON / OFF] Inactive voltage 0 - 0.5 V
[ON / OFF] Active voltage 5 - 12 V
[ON / OFF] Input current - 1 - mA
[ON] Activation time 200 - 600 ms
The following examples show how to use remote ON/OFF.
NOTE:
A special feature in the software can be used to load and start pro-
grams automatically, see part II.
UR5/CB3 I-30 Version 3.1 (rev. 17782)
Copyright © 2009-2015 by Universal Robots A/S. All rights reserved.

Table of Contents

Other manuals for Universal Robots UR5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Universal Robots UR5 and is the answer not in the manual?

Universal Robots UR5 Specifications

General IconGeneral
BrandUniversal Robots
ModelUR5
CategoryRobotics
LanguageEnglish

Related product manuals