EasyManuals Logo

Volvo Penta D6 User Manual

Volvo Penta D6
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #100 background imageLoading...
Page #100 background image
Helm station change
1 Move the control lever(s) to neutral (N).
The neutral lamp (1) on the control lights up when
the drive is in neutral.
2 If the helm station is locked, unlock it by pressing
the STATION button (2). The padlock icon light (3)
is switched off, indicating that the station is
unlocked.
3 Activate the helm station being occupied by
pressing the STATION button (2).
The lamp in the control button will light up when the
helm station is active.
If the helm station is inactive, the lamp will be switched
off.
If the padlock icon (3) flashes, the helm station cannot
be activated. Another helm station is active and locked,
or unlocked with a drive selected (not in neutral).
Locking/Unlocking Helm Stations
If a helm station is locked, it will only be possible to start
and stop the engine or change helm stations from the
locked helm station.
Lock or unlock an active helm station by pressing the
STATION button (2).
The padlock icon (3) lights up when the helm station is
locked.
Helm station priority
There are three different types of helm station a boat
can be steered from.
Local station
The local helm station has superiority over both the
main helm station and remote helm station. The local
helm station is always able to take over control from
another active helm station without unlocking the
active helm station first.
If there is an additional local helm station that is active
it must first be unlocked in order to transfer control to
another local helm station.
Main station
The main helm station has superiority over the remote
helm station but is subordinate to the local helm
station.
In order for the main helm station to take control from
an active local helm station or another main helm
station the active helm station must be unlocked first.
The main helm station can take control from a remote
helm station without unlocking the remote helm station.
Remote station
The remote helm station is subordinate to the local
helm station and the main helm station.
The active helm station must first be unlocked in order
to activate the remote helm station.
Operation
96 47712786 11-2022 © AB VOLVO PENTA

Table of Contents

Other manuals for Volvo Penta D6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Volvo Penta D6 and is the answer not in the manual?

Volvo Penta D6 Specifications

General IconGeneral
Bore x Stroke103 mm x 110 mm
AspirationTurbocharged
Fuel SystemCommon rail
Compression Ratio17.5:1
Displacement5.5L
Max Power480 HP
Engine TypeIn-line 6-cylinder diesel