55
Repair Instructions
Timing cover outer,
replacement (15A-01)
1
Disconnect the battery.
2
Remove the generator (GEN) drive belt, operation
22A-03.
3
Remove the pulley for the water pump.
4
Remove the inspection hatch from the timing cover
(15A.04/A).
5
Remove the clips for the cover and remove the cap
(A).
6
Check that the cap is clean and that all the spring
clips are fastened at the timing cover.
7
Install the cap on the timing cover and ensure that
all the clips are in position.
8
Install the inspection hatch on the timing cover and
the cap.
9
Install the water pump belt.
10
Install the generator (GEN) belt, operation 22A-03.
11