Technical Data E 2200, E 3000ES
110 wc_td000422gb.fm
9 Technical Data
9.1 E 2200
E 2200 Units
Item No.
0620176
Item No.
0620215
Item No.
0620216
Item No.
0620226
Weight, no fuel, no genera-
tor
kg (lb) 2139 (4715)
Weight, full fuel, no genera-
tor
kg (lb) 2618 (5772)
Generator weight
kg (lb) n/a n/a 238 (525)
Fuel tank capacity
L (gal) 572 (151)
Hose length
m (ft) 670 (2200)
Hose loops
qty 2
HTF capacity
L (gal) 360 (95)
HTF Pump
L/hr (gph) 2 X 1003
(2 X 265)
Burner make/model
— Beckett / AFG GH106
Burner nozzle
gph X deg 1.35 70° B
Fuel pressure
bar (psi) 12.4 (180)
Fuel input
kW/hr
(BTU)/hr
74
252,000
Heat output
kW/hr
(BTU)/hr
65
220,000
Heater efficiency
%87
Run time (up to)
hr 130
Hose pressure
bar (psi) 4.8–6.2 (70–90)
Standard thaw capacity
m
2
(ft
2
) 204–409 (2200–4400)
Accelerated thaw capacity
m
2
(ft
2
) 409 (4,400)
Standard cure capacity
m
2
(ft
2
) 409 (4,400)
Expanded cure capacity
m
2
(ft
2
) 1,226 (13,200)
Standard frost prevention
m
2
(ft
2
) 836 (9,000)
Expanded frost prevention
m
2
(ft
2
) 1,839 (19,800)
Air heat capacity
m
3
(ft
3
) 10,194 (360,000)