BA 1404 en – Edition 2.7 * 1404b340.fm 3-65
Operation
Right-hand control lever
Emergency lowering
Crushing hazard during boom lowering!
Causes serious crushing or injury resulting in death.
☞ Ensure that no one is in the danger zone.
Observe the following during emergency lowering:
1 Turn the starting key to position 1.
2 Lower both control lever bases.
3 Push the right-hand control lever 6 forward until the boom is fully lowered to the
ground.
4 Return the control lever to neutral.
Abb. 134:Control lever on the right
H
G
E
F
6
J
Position Lever Function
•E ☞ Forward ➥ Boom is lowered
•F ☞ To the right ➥ Tilt out the bucket
•G ☞ Backward ➥ Boom is raised
•H ☞ To the left ➥Tilt in the bucket
Button Function
☞ J ➥ Horn
Abb. 135: Emergency lowering
6