6-10 BA 1404 en – Edition 2.7 * * 1404b610.fm
Technical data
6.12 Lift capacity tables
Safety instructions – lift capacity tables
Danger!
Danger of crushing due to tipping over of machine!
Causes serious crushing or injury resulting in death.
The authorized lift capacity specified in the table must never be exceeded.
The lowest value applies.
Get informed on the lift capacity of the attachment before using it.
If a bucket or attachment (hammer, etc.) is installed, the dead weight and
the contents of the bucket must be subtracted from the lift capacity speci-
fied in the table. Load density must also be taken into account.
All lifting gear applications are forbidden with this machine.
Caution!
If the specified lift capacity is exceeded, danger of damage to property due to
tipping over of machine.
The authorized lift capacity specified in the table must never be exceeded.
The lowest value applies.
Notice!
The indications are only approximate values. Attachments, uneven ground and
soft or bad ground conditions affect lift capacity. The operator must take these
influences into account.
All table indications in kg (lbs) and horizontal position on firm and level ground, and without
bucket or attachment.
Calculation basis: according to ISO 10567.
Preset pressure on boom cylinder: 20000 kPa (2,900 psi)
The machine’s lift capacity is restricted by the hydraulic output and the hydraulic system’s
stabilizing features.
Neither 75 % of the static tilt load nor 87 % of the hydraulic lift capacity is exceeded.
The lift capacity applies under the following conditions:
Lubricants and engine/machine fluids at the mandatory levels.
Full fuel tank.
Canopy or cab.
Machine at operating temperature.
Operator weight 75 kg (165 lbs).
Abb. 219: Lift capacity table
A Reach from live ring center
B Height

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson E09-01 and is the answer not in the manual?

Wacker Neuson E09-01 Specifications

General IconGeneral
BrandWacker Neuson
ModelE09-01
CategoryExcavators
LanguageEnglish

Related product manuals