Virtex-5 RocketIO GTP Transceiver User Guide www.xilinx.com 253
UG196 (v1.3) May 25, 2007
HM-Zd Design Example
R
The right-angle connectors have P/N length differences in the signal paths, as shown in
Figure 14-3, that require PCB trace lengths to be adjusted to compensate for the skew.
Figure 14-4 shows an example design where the traces are preskewed to compensate for
P/N length mismatches within the connector body.
Figure 14-2: Tyco Z-PACK HM-Zd Press-Fit Connector
Figure 14-3: Tyco Z-PACK HM-Zd Press-Fit Connector Internals
UG196_c14_02_051406
UG196_c14_03_051406