5.2 Motor Performance Fine Tuning
This section offers helpful information for counteracting oscillation, hunting, or other faults
that occur while performing a trial run.
Note: This section describes parameters that are commonly edited. Consult Yaskawa for more information on
detailed settings and fine-tuning the drive.
u
Parameters for Tuning the Drive
Table 5.1 Parameters for Tuning the Drive
Problem Parameter No. Corrective Action
Default
Value
Suggested
Setting
Motor hunting and
oscillation at speeds
between 10 and 40 Hz
Hunting
Prevention Gain
(n1-02)
If insufficient motor torque relative to the
size of the load causes hunting, reduce the
setting.
When motor hunting and oscillation occur
with a light load, increase the setting.
Lower this setting if hunting occurs when
using a motor with a relatively low
inductance, such as a high-frequency motor
or a motor with a larger frame size.
1.00 0.10 to 2.00
Motor noise
Motor hunting and
oscillation at speeds up
to 40 Hz
Carrier
Frequency
Selection
(C6-02)
If the motor noise is too loud, increase the
carrier frequency.
When motor hunting and oscillation occur at
speeds up to 40 Hz, lower the carrier
frequency.
The default setting for the carrier frequency
depends on the drive capacity (o2-04) and the
Drive Duty Selection (C6-01).
7 (Swing
PWM)
1 to 7
Poor motor torque at
speeds below 10 Hz
Motor hunting and
oscillation
Torque
Compensation
Gain (C4-01)
If motor torque is insufficient at speeds
below 10 Hz, increase the setting.
If motor hunting and oscillation with a
relatively light load, decrease the setting.
1.00 0.50 to 1.50
Poor motor torque at
low speeds
Motor instability at
motor start
Mid Output
Voltage A
(E1-08)
Minimum
Output Voltage
(E1-10)
If torque is insufficient at speeds below 10
Hz, increase the setting.
If motor instability occurs at motor start,
decrease the setting.
Note: The recommended setting value
is for 200
V class drives. Double this value when using a
400 V class drive.
E1-08:
16.0 V
E1-10:
12.0 V
Initial value
±5 V
Poor speed precision
Slip
Compensation
Gain (C3-01)
After setting the motor-rated current (E2-01),
motor-rated slip (E2-02) and motor no-load
current (E2-03), adjust the slip compensation
gain (C3-01).
- 0.5 to 1.5
u
Motor Hunting and Oscillation Control Parameters
The following parameters indirectly affect motor hunting and oscillation.
5.2 Motor Performance Fine Tuning
YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual
121
5
Troubleshooting
2/6/2008-14:44

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA CIMR-JA Series and is the answer not in the manual?

YASKAWA CIMR-JA Series Specifications

General IconGeneral
BrandYASKAWA
ModelCIMR-JA Series
CategoryController
LanguageEnglish

Related product manuals