5.3 Drive Alarms, Faults, and Errors
u
Types of Alarms, Faults, and Errors
Check the LED operator for information about possible faults if the drive or motor fails to
operate. Refer to Using the Digital LED Operator on page 73.
If problems occur that are not covered in this manual, contact the nearest Yaskawa
representative with the following information:
Drive model
Software version
Date of purchase
Description of the problem
Table 5.3 contains descriptions of the various types of alarms, faults, and errors that may occur
while operating the drive.
Contact Yaskawa in the event of drive failure.
Table 5.3 Types of Alarms, Faults, and Errors
Type Drive Responses to Alarms, Faults, and Errors
Faults
When the drive detects a fault:
The digital operator displays text that indicates the specific fault and the ALM indicator LED
remains lit until the fault is reset.
The fault interrupts drive output and the motor coasts to a stop.
Depending on the setting, the drive and motor may stop via different methods than listed.
If a digital output is programmed for fault output (H2-01 = E), it will close if a fault occurs.
When the drive detects a fault, it will remain inoperable until that fault has been reset. Refer to
Fault Reset Methods on page 142.
Minor Faults and
Alarms
When the drive detects an alarm or a minor fault:
The digital operator displays text that indicates the specific alarm or minor fault and the ALM
indicator LED flashes.
The motor does not stop.
The multi-function contact output
closes if set to be tripped by a minor fault (H2-01 = 10), but
not by an alarm.
The digital operator displays text indicating a specific alarm and ALM indicator LED flashes.
Remove the cause of an alarm or minor fault to automatically reset.
Operation Errors
When parameter settings conflict with one another or do not match hardware settings (such as with
an option unit), it results in an operation error.
When the drive detects an operation error:
The digital operator displays text that indicates the specific error.
The multi-function contact output does not operate.
When the drive detects an operation error, it will not operate the motor until the error has been
reset. Correct the settings that caused the operation error to reset.
5.3 Drive Alarms, Faults, and Errors
YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual
123
5
Troubleshooting
2/6/2008-14:44

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA CIMR-JA Series and is the answer not in the manual?

YASKAWA CIMR-JA Series Specifications

General IconGeneral
BrandYASKAWA
ModelCIMR-JA Series
CategoryController
LanguageEnglish

Related product manuals