EasyManuals Logo
Home>YASKAWA>Controller>CIMR-JA Series

YASKAWA CIMR-JA Series User Manual

YASKAWA CIMR-JA Series
248 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #99 background imageLoading...
Page #99 background image
Step Display/Result
6.
Press to run the motor at 5 Hz. The RUN light will turn on.
STOP
Off On
7.
With SW1 closed, the drive runs the motor at Multi-Step Speed 2
(20 Hz).
8.
With SW1 open and SW2 closed, the drive runs the motor at Multi-Step
3 (50 Hz).
9.
With both SW1 and SW2 closed, the drive runs the motor at Multi-Step
4 (60 Hz).
10.
Press
STOP
to stop the drive. The RUN light will flash until the
motor comes to a complete stop.
STOP
Flashing Off
<1> When the frequency reference is assigned to the LED operator (b1-01=0), the first step in a multi-step speed
sequence comes from d1-01.
Note: When a run command is input from the control circuit terminal, the frequency reference value is selected
as follows:
When b1-01 = 0 and the run command is given, the drive uses the frequency set to d1-01.
When b1-01 = 1 and the run command is given, the drive uses the frequency reference value input to analog
control terminal A1.
u
Drive Input Voltage Setting: E1-01
Set E1-01 according to the power supply
voltage. This setting serves as a base value for certain
drive protective functions.
NOTICE: Set drive input voltage (not motor voltage) in parameter E1-01 for proper function of the protective
features of the drive. Failure to comply could result in improper drive operation. Set parameter E1-01 to match
the input voltage of the drive.
Parameter Name Description Setting Range Default
E1-01
Input
Voltage
Setting
Set to the nominal voltage of the incoming line. Sets
the maximum and base voltage, and adjusts the levels
of drive protective features (e.g., overvoltage, braking
resistor level, stall prevention, etc.).
200 V Class: 155 to 255
400 V Class: 310 to 510
200 V
4.5 Basic Operation
YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual
99
4
Start-Up Programming
& Operation
2/6/2008-14:44

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA CIMR-JA Series and is the answer not in the manual?

YASKAWA CIMR-JA Series Specifications

General IconGeneral
BrandYASKAWA
ModelCIMR-JA Series
CategoryController
LanguageEnglish

Related product manuals