u
d: References
Reference parameters are used to set the various frequency reference values during operation.
No. Name Description Range Def.
Mode
Addr.
Hex
Pg.
V/f
d1: Frequency Reference
Use d1 parameters to configure the drive frequency reference.
d1-01
<22>
Frequency
Reference 1
Frequency reference
0.00 to
400.00
Hz
<19>
0.00
Hz
S 280 96
d1-02
<22>
Frequency
Reference 2
Frequency reference when digital input "Multi-Step
Speed Reference 1" (H1-oo = 3) is on.
0.00
Hz
S 281 96
d1-03
<22>
Frequency
Reference 3
Frequency reference when digital input "Multi-Step
Speed Reference 2” (H1-oo = 4) is on.
0.00
Hz
S 282 96
d1-04
<22>
Frequency
Reference 4
Frequency reference when digital inputs "Multi-Step
Speed Reference 1, 2" (H1-oo = 3 and 4) are on.
0.00
Hz
S 283 96
d1-05
<22>
Frequency
Reference 5
Frequency reference when digital input "Multi-Step
Speed Reference 3" (H1-oo = 5) is on.
0.00
Hz
O 284 —
d1-06
<22>
Frequency
Reference 6
Frequency reference when digital inputs "Multi-Step
Speed Reference 1, 3 " (H1-oo = 3 and 5) are on.
0.00
Hz
O 285 —
d1-07
<22>
Frequency
Reference 7
Frequency reference when digital inputs "Multi-Step
Speed Reference 2, 3" (H1-oo = 4 and 5) are on.
0.00
Hz
O 286 —
d1-08
<22>
Frequency
Reference 8
Frequency reference when multi-function input
"Multi-Step speed reference 1, 2, 3" (H1-oo = 3, 4,
5) are on.
0.00
Hz
O 287 —
d1-17
<22>
Jog Frequency
Reference
Frequency reference when digital inputs "Jog
Frequency Reference", "Forward Jog" or "Reverse
Jog." are on.
6.00
Hz
S 292 —
d2: Frequency Upper and Lower Limits
Use d2 parameters to configure the frequency reference limits.
d2-01
Frequency
Reference
Upper Limit
Sets the frequency reference upper limit as a
percentage of maximum output frequency (E1-04).
Output speed is limited to this value even if the
frequency reference is higher. This limit applies
to all
frequency reference sources.
0.0 to
110.0
100.0
%
O 289 —
d2-02
Frequency
Reference
Lower Limit
Sets the frequency reference lower limit as a
percentage of maximum output frequency (E1-04).
Output speed is limited to this value even if the
frequency reference is lower. This limit applies to all
frequency reference sources.
0.0 to
110.0
0.0% O 28A —
d3: Jump Frequency
Use d3 parameters to configure the drive Jump Frequency settings.
d3-01
Jump
Frequency 1
d3-01 to d3-04 allow programming of three prohibited
frequency reference points for eliminating problems
with resonant vibration of the motor/machine. This
feature does not eliminate the selected frequency
values, but accelerates and decelerates the motor
through the prohibited bandwidth.
The parameters must be according to the rule
d3-01 ≥ d3-02 .
0.0 to
400.0
0.0
Hz
O 294 —
d3-02
Jump
Frequency 2
0.0
Hz
O 295 —
B.2 Parameter Table
YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual
203
B
Parameter List
2/6/2008-14:44