Power Up
Frequency Reference
STOP
Default Setting
This display screen allows the user to monitor and set the frequency
reference while the drive is running. Refer to The Drive and
Programming Modes on page 78.
Note: The user can select items to display when the drive is first
powered up by setting parameter o1-02.
Drive Mode
Forward/Reverse
: Motor rotates forward.
: Motor rotates in reverse.
Note: For applications that should not run in reverse (fans, pumps,
etc.), set parameter b1-04 = “1” to prohibit the motor from rotating in
reverse. This sequence also puts the drive in LOCAL mode.
The LED is lit when
LOCAL is selected
Switching to reverse:
Output Frequency Display
Monitors the frequency output by the drive.
Output Current Display
Monitors the output current of the drive.
Drive Mode
Output Voltage Reference
Monitors the output voltage of the drive.
Monitor Display
Monitor parameters (U parameters) are displayed.