Preventive daily maintenance
Fuel system leaks
Engine oil level
Cooling system
Perform this maintenance daily or after every 8 - 10 hours
of operation at the latest.
NM13N083
Check the fuel system for leaks, including the fuel tank.
Repair any leaks immediately. The hole for draining dirt
from the fuel tank is found in its bottom.
Perform a check on a daily basis before putting into
operation, making the tractor stable on a flat surface with
the engine off. The engine oil gauge (1) is located on the
left-hand side of the engine.
Pull out the gauge (1), wipe it with a clean fibreless rag
and slip it fully back in.
After pulling out the gauge once again check the oil level.
The oil level must be always between MIN and MAX.
You can top up the oil if need be.
NM14D006
Check the connections of the engine cooling system for
leaks and the coolant quantity in the expansion tank.
Replenish the missing quantity up to the upper mark
indicated MAX. The minimum acceptable cooling liquid
level is indicated by the MIN mark.
Only release the overpressure plug when the
coolant has cooled down! There is a danger of
scalding!
PREVENTIVE DAILY MAINTENANCE
21

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zetor MAJOR and is the answer not in the manual?

Zetor MAJOR Specifications

General IconGeneral
Hydraulic SystemOpen center
Displacement4.156 l
Number of Cylinders4
PTO Speed540/1000 rpm
Engine TypeZetor
EngineZetor

Related product manuals