Operation Manual / A200-L
5 Monitoring during operation / 5.4 Low pressure measurement at the
filter silencer
© Copyright 2021 ABB. All rights reserved. HZTL4036_EN Rev.T December 2021
5.3.5 Malfunction of the speed measurement system
The possible reasons for malfunction of the speed measuring system are described in
chapter Troubleshooting.
5.4 Low pressure measurement at the filter silencer
5.4.1 Introduction
The low pressure measurement with a U-tube manometer is used for the following pur-
poses:
¡ During acceptance test of the engine: Measurement of the correction factor for the cal-
culation of the turbocharger efficiency
¡ When using a filter mat: An increased pressure loss indicates an increase in the fouling of
the filter material.
5.4.2 U-tube manometer at the filter silencer
Fig.14: U-tube manometer at the filter silencer
81000 Filter silencer
81050 U-tube manometer
A [mm H
2
O] Pressure loss / pressure difference
If the turbocharger is operated at maximum engine power and pressure loss (A) reaches the
value of 200mmH
2
O:
u Clean filter mat.
Reading of pressure loss
For simple reading of the pressure loss (A), the dipstick at the U-tube manometer can be
pulled out to the level of the lower water level. Better readability of the U-tube manometer
can be achieved by filling with slightly coloured water.
u Colour the water with food colouring or ink.
Page 40 / 145

Table of Contents

Other manuals for ABB A200-L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB A200-L and is the answer not in the manual?

ABB A200-L Specifications

General IconGeneral
BrandABB
ModelA200-L
CategoryBattery Charger
LanguageEnglish

Related product manuals