6.3 Expected replacement intervals
6.3.1 Replacement intervals
Expected replacement intervals [h]
Turbocharger part Operation with HFO *)
Gas inlet casing 50000 … 100000
Gas outlet casing 50000 … 100000
Nozzle ring 35000 … 50000
Cover ring 25000 … 50000
Other casings 100000
Table11: Expected replacement intervals for turbocharger parts
*) HFO = Heavy Fuel Oil
Recommended replacement intervals [h]
Rotor components See information on rating plate
Bearings See information on rating plate
Table12: Recommended replacement intervals for turbocharger parts
The specified values are guideline values and not guaranteed values, see Influencing para-
meters.