Chapter 3 - Handling of Control Panel CDP 312
IV F
3 - 16 DCS 600 Operating Instructions
3.13 Drive Mode
Display of the ID-number for the Drive and for the Control Panel CDP 312
as well as display of the status (Status Display):
Step Function Press key Display after key is
pressed
1.
To enter the Drive Mode
DRIVE
.-= 
3.8?7,/<
>9>+6.<3@/=
2.
To select the Status Display (see
table below):
To change the ID number of the
drive (the ID-Number will appear
in brackets) and then ...
to select the new value.
To accepted the new value.
The power of the DCS 600 must
be switched OFF to validate its
new ID-Number setting (the new
value is not displayed until the
power is switched OFF and ON).
The Status Display of all drives
connected to the Panel Link is
shown after the last individual
drive.
If all drives do not fit on the dis-
play at once, press the arrow
keys to show the rest of them.
ENTER
ENTER
.-= 
3.8?7,/<EG
>9>+6.<3@/=

pon
0
 
! " #

nn
pnnn
3.
To cancel the Drive Mode.
The selected Keypad Mode is
entered.
ACT
PAR
FUNC
DRIVE
Table: Symbols of Status Display
Symbol Status Display
o
Stopped, main contactor OFF (open)
p
Stopped, main contactor ON (closed)
n
Running, main contactor ON (closed)
0
Alarm or fault signalling effective in the drive

Table of Contents

Other manuals for ABB DCS 600 MultiDrive

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB DCS 600 MultiDrive and is the answer not in the manual?

ABB DCS 600 MultiDrive Specifications

General IconGeneral
BrandABB
ModelDCS 600 MultiDrive
CategoryMedia Converter
LanguageEnglish

Related product manuals