4 Repair
4.3.3. Fitting cable package attachments (Cleanroom)
3HAC026876-001 Revision: F216
© Copyright 2007-2010 ABB. All rights reserved.
4.3.3. Fitting cable package attachments (Cleanroom)
Overview
This section details how to fit the cable attachments for the cable harness (Cleanroom). How
to replace the cable harness itself is detailed in section Replacement of cable harness,
Cleanroom on page 224.
Location of cable harness attachments (Cleanroom)
The cable harness attachments are located as shown in the figure below.
xx0800000022
Required equipment
A Shelf
B Gripping clamp
C Side bracket balancing cylinder
D Lower bracket
E Gripping clamp
F Bracket for cable clamp
G Gripping clamp
H Gripping clamp
J Bracket for cable clamp
K Cable guide
L Connection plate axis 3
Equipment Part no. Note
Locking liquid - Loctite 243
Standard toolkit - The content is defined in the section
Standard toolkit on page 409.
Other tools and procedures may be
required. See references to these
procedures in the step-by-step
instructions below.
These procedures include
references to the tools required.
Continues on next page