8 TTF300 FIELD-MOUNT TEMPERATURE TRANSMITTER | OI/TTF300-EN REV. I
… 2 Use in potentially explosive atmospheres in accordance with ATEX and IECEx
Temperature data
Transmitter
ATEX / IECEx intrinsic safety, ATEX increased safety as well
as dust explosion protection (Zone 22)
Permissible ambient temperature range
−50 to 56
−50 to 85
(−58 to 185.0
ATEX / IECEx flameproof (enclosure)
Permissible ambient temperature range on the
connection head
−40 to 67
−40 to 85
LCD indicator
ATEX / IECEx intrinsic safety
Permissible ambient temperature range
−50 to 56
(−58 to 132.8
−50 to 85
Electrical data
Transmitter
Intrinsic safety type of protection Ex ia IIC (Part 1)
TTF300-
TTF300-
TTF300-E1P/-
TTF300-E1F/-
-circuit current I
I
I
L
L
L
* II B FISCO: I
i
≤ 380 mA, P
i
≤ 5.32 W
** Only applies to HART variant. From HW-Rev.: 02.00, previously 0.5 mH
*** Only applies for HART variants. From HW-Rev.: 1.07, previously 5 nF
Intrinsic safety type of protection Ex ia IIC (Part 2)
TTF300-E1H, TTF300-H1H measurement current circuit model
Resistance
thermometers, resistors
-circuit current I
= 17.8 mA
I
L
i
L
i
Maximum permissible
external inductance
L
o
L
o
Maximum permissible
external capacitance
C
o
= 1.65 μF
C
o
= 1.15 μF
1 From HW-Rev.: 02.00, previously 25 mA
2 From HW-Rev.: 02.00, previously 38 mW
3 From HW-Rev.: 02.00, previously 1.55 μF
4 From HW-Rev.: 02.00, previously 1.05 μF