291
Chapter 5 Error Messages
Execution Errors
4
5
-221 Settings conflict;
FSK turned off by selection of other mode or modulation
The function generator will allow only one modulation, sweep, or burst
mode to be enabled at the same time. When you enable a modulation,
sweep, or burst mode, all other modes are turned off.
-221 Settings conflict;
FM turned off by selection of other mode or modulation
The function generator will allow only one modulation, sweep, or burst
mode to be enabled at the same time. When you enable a modulation,
sweep, or burst mode, all other modes are turned off.
-221 Settings conflict;
AM turned off by selection of other mode or modulation
The function generator will allow only one modulation, sweep, or burst
mode to be enabled at the same time. When you enable a modulation,
sweep, or burst mode, all other modes are turned off.
-221 Settings conflict;
PM turned off by selection of other mode or modulation
The function generator will allow only one modulation, sweep, or burst
mode to be enabled at the same time. When you enable a modulation,
sweep, or burst mode, all other modes are turned off.
-221 Settings conflict;
PWM turned off by selection of other mode or modulation
The function generator will allow only one modulation, sweep, or burst
mode to be enabled at the same time. When you enable a modulation,
sweep, or burst mode, all other modes are turned off.
-221 Settings conflict;
sweep turned off by selection of other mode or modulation
The function generator will allow only one modulation, sweep, or burst
mode to be enabled at the same time. When you enable a modulation,
sweep, or burst mode, all other modes are turned off.
-221 Settings conflict;
not able to modulate this function
The function generator cannot generate an AM, FM, PM, or FSK
modulated waveform using the pulse, noise, or dc voltage functions.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 33220A and is the answer not in the manual?

Agilent Technologies 33220A Specifications

General IconGeneral
BrandAgilent Technologies
Model33220A
CategoryInverter
LanguageEnglish

Related product manuals