Commissioning 51/72
RE 92050-01-X-B1/2019.08.23, Axial piston variable pump A4VSO, BoschRexrothAG
8.1.6 Performing flushing cycle
In order toremove foreign particles from thesystem, BoschRexroth recommends
aflushing cycle for theentire system prior toinitial commissioning. To avoid internal
contamination, do not include theaxial piston unit inthe flushing cycle.
Use anadditional flushing unit toperform theflushing cycle. Follow
theinstructions oftheflushing unit's manufacturer for theexact procedure during
theflushing cycle.
8.2 Running-in phase
NOTICE
Property damage due toinsufficient viscosity!
Elevated hydraulic fluid temperature may excessively reduce viscosity and damage
theproduct!
Monitor the operating temperature during the running-in phase,
e.g.bymeasuring the case leakage temperature.
Reduce theloading (pressure, rotational speed) oftheaxial piston unit
ifunacceptable operating temperatures and/or viscosities occur.
Excessively high operating temperatures indicate faults that have tobe analyzed
and eliminated.
The bearings and sliding surfaces are subject toarunning-in phase. The increased
friction atthestart oftherunning-in phase results inincreased heat development
which decreases over time. Volumetric and mechanical-hydraulic efficiency isalso
greater until therunning-in phase ofabout 10operating hours isconcluded.
To ensure contamination in the hydraulic system does not damage the axial piston
unit, the following procedure is recommended after the running-in phase:
After therunning-in phase, have ahydraulic fluid sample analyzed for therequired
cleanliness level.
Change thehydraulic fluid iftherequired cleanliness level isnot reached. If
alaboratory test is not carried out after the running-in phase, it is recommended
to change the hydraulic fluid.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch rexroth A4VSO 10 Series and is the answer not in the manual?

Bosch rexroth A4VSO 10 Series Specifications

General IconGeneral
BrandBosch
Modelrexroth A4VSO 10 Series
CategoryWater Pump
LanguageEnglish

Related product manuals