ctrlX SAFETY "SafeMotion"
Safe zone error (SZE)
Bosch Rexroth AG
R911404905,
Edition 02
A pending zone error is transferred to the zone master via a ctrlX SAFETYlink
and is available as sum signal via the error state for zone nodes for further
processing. This sum signal is provided to all zone nodes.
Features
The safety function "Safe zone error" (SZE) has the following features:
The safety function is intended for safety-relevant applications up to
Category 4, PL e according to EN ISO 13849-1 or up to SIL 3 according
to EN 62061.
The safety level achieved for the safety function "Safe zone error" (SZE)
depends on the safety level achieved in the zone nodes. The zone node with
the lowest safety level determines the safety level of the Safe zone error.
To use the safety function "Safe zone error" (SZE), a safety zone generated
via the ctrlX SAFETYlink is required.
The safety function "Safe zone error" (SZE) can only be used in axes of the
ctrlX DRIVEplus ranges equipped with the optional safety technology module
"M5".
The safety function "Safe zone error" (SZE) can only be used in connection
with the safe function " Safety zone acknowledge (SZA)".
Quick transmission of safety technology error messages within the safety
zone.
Free configuration option as regards error messages and error acknowledg-
ment.
Parameters involved
The following parameters can be used in conjunction with the safety function
"Safe zone error":
P‑0‑3266.0.1, SMO: Control word safety zone
P‑0‑3266.0.2, SMO: Configuration of safety zone
P‑0‑3321, SMO: Safe output signals, SAFETYLink
Diagnostic messages involved
The following diagnostic messages can be generated in conjunction with the
safety function "Safe zone error":
F7035 SAFETYlink errror
E8300 SMO: Error within the safety zone
9.8.2
Safety function
Configuration
To use the safety function "Safe zone error" (SZE), it has to be configured via
the parameter “P-0-3266.0.2, SMO: Configuration of safety zone“. The following
configurations can be set individually for each zone node:
Zone node signals zone error and reacts to zone error (type 1)
Zone node only signals zone error (type 2)
Zone node only reacts to zone error (type 3)
Zone node does not signal any zone error and does not react to zone error
either (type 4)
Monitoring function
According to the configuration, the zone nodes react differently to their own
errors and zone errors:
Type 1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch rexroth ctrlX SAFETY SafeMotion and is the answer not in the manual?

Bosch rexroth ctrlX SAFETY SafeMotion Specifications

General IconGeneral
BrandBosch
Modelrexroth ctrlX SAFETY SafeMotion
CategoryService Equipment
LanguageEnglish

Related product manuals