EasyManuals Logo

BRP Evinrude E-TEC G2 150 HP User Manual

BRP Evinrude E-TEC G2 150 HP
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #34 background imageLoading...
Page #34 background image
32
Boat Rigging
Battery Installation
Support the battery switch as needed to prevent
abrasion.
Use appropriate wiring and connectors.
Seal all connections and terminals with liquid
neoprene to prevent corrosion.
Battery Switch Operation
Select the primary battery for normal operation.
Secondary batteries should only be selected for
emergency starting.
ALL or BOTH switch position is for emergency
starting only.
Provide operator with the documentation supplied
by the battery switch manufacturer. Make sure
that the operator is informed of proper battery
switch operation.
Auxiliary Battery Charging
Evinrude E-TEC G2 outboards are equipped with
isolated battery charging capability. The isolated
charge connection must only be used to charge a
single 12-volt battery or two 12-volt batteries wired
in parallel.
The auxiliary battery charging kit provides a maxi-
mum of 25 Amps to the auxiliary battery.
Accessory Charge Lead Kit, P/N 5009079, is
routed from a connector on the outboard’s electri-
cal harness to the accessory battery.
NOTICE
Never connect an external battery isolator to
the stator of an Evinrude E-TEC G2.
NOTICE
The accessory charging kit must never be
connected to any battery of a 24-volt electri-
cal system.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BRP Evinrude E-TEC G2 150 HP and is the answer not in the manual?

BRP Evinrude E-TEC G2 150 HP Specifications

General IconGeneral
BrandBRP
ModelEvinrude E-TEC G2 150 HP
CategoryOutboard Motor
LanguageEnglish

Related product manuals