1-73
Cisco ASR 901 Aggregation Services Router Command Reference Guide
OL-26031-07
Chapter 1 CLI Command Reference
network-clock hold-off
network-clock hold-off
To configure general hold-off timer in milliseconds, use the network-clock hold-off command in the
interface configuration mode. Use the no form of the command to remove the configuration.
network-clock hold-off {0 | <50-10000>}
no network-clock hold-off {0 | <50-10000>}
Syntax Description
Command Default The default value is 300 milliseconds.
Command Modes Interface configuration
Command History
Usage Guidelines Displays a warning message for values below 300 ms and above 1800 ms.
Examples This example configures the hold-off timer:
Router(config-if)#network-clock hold-off 1000
Related Commands
<50-10000> Sets the hold-off timer. The default value is 300 milliseconds.
Release Modification
15.1(2)SNG Support for this command was introduced on the Cisco ASR 901 router.
Command Description
network-clock
synchronization ssm
option
Configures the router to work in a synchronized network mode as described
in G.781.