269
Chapter 17: Managing Device Diagnostics
SGE2000/SGE2000P Gigabit Ethernet Switch Reference Guide
Chapter
17
Managing Device Diagnostics
This section contains information for configuring port mirroring, running cable tests, and viewing device
operational information, and includes the following topics:
Viewing Integrated Cable Tests
Performing Optical Tests
Configuring Port Mirroring
Defining CPU Utilization
Viewing Integrated Cable Tests
The Copper Ports Page contains fields for performing tests on copper cables. Cable testing provides information
about where errors occurred in the cable, the last time a cable test was performed, and the type of cable error that
occurred. The tests use Time Domain Reflectometry (TDR) technology to test the quality and characteristics of a
copper cable attached to a port. Cables up to 120 meters long can be tested. Cables are tested when the ports are in
the down state, with the exception of the Approximated Cable Length test.
To test cables:
1. Click Admin > Diagnostics > Copper Ports. The Copper Ports Page opens:
Copper Ports Page
The Copper Ports Page contains the following fields:
Unit No. — Indicates the unit number on which the tests are performed.

Table of Contents

Other manuals for Cisco SGE2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SGE2000 and is the answer not in the manual?

Cisco SGE2000 Specifications

General IconGeneral
BrandCisco
ModelSGE2000
CategoryNetwork Router
LanguageEnglish

Related product manuals