Step: 1
Range: 0 - 10000
Default: 0
7.6.3 LoadRequest 1 [-]
Regulator requested value.
Step: 1
Range: -10000 - +10000
Default: 90
7.6.4 Load request 2 [-]
Regulator requested value when LBI LoadRequest2 is active
Step: 1
Range: -10000 - +10000
Default: 80
7.6.5 LoadReq Ramp [1/s]
Ramp when is switched between LoadRequest 1 and LoadRequest 2.
Step: 1 1/s
Range: 1 - 10000 1/s
Default: 1000
7.6.6 LoadUpLimit [-]
Load limit regulator PI output upper limit.
Step: 1
Range: 0 - 10000
Default: 10000
7.6.7 LoadDnLimit [-]
Load limit regulator PI output low limit.
Step: 1
Range: 0 - 10000
Default: 0
7.6.8 Load Gain [%]
This is setpoint is giving Load limit gain factor.
Step: 0.1
Range: -200.0% - +200.0%