Functions SiUS041111
2 List of Functions
1. Functions
Category Functions
FTXN09/12KEVJU
RKN09/12KEVJU
FTXN09/12KEVJU
RXN09/12KEVJU
Category Functions
FTXN09/12KEVJU
RKN09/12KEVJU
FTXN09/12KEVJU
RXN09/12KEVJU
Basic Function Inverter (with Inverter Power Control) Health &
Clean
Air-Purifying Filter — —
Operation Limit for Cooling (°FDB)
50 ~
114.8
50 ~
114.8
Photocatalytic Deodorizing Filter — —
Operation Limit for Heating (°FWB) —
5 ~
64.4
Air-Purifying Filter with Photocatalytic
Deodorizing Function
——
PAM Control
Titanium Apatite Photocatalytic
Air-Purifying Filter
Standby Electricity Saving
Compressor Oval Scroll Compressor — — Air Filter (Prefilter)
Swing Compressor Wipe-Clean Flat Panel
Rotary Compressor — — Washable Grille — —
Reluctance DC Motor MOLD PROOF Operation — —
Comfortable
Airflow
Power-Airflow Louver (Horizontal Blade) Good-Sleep Cooling Operation — —
Power-Airflow Dual Louvers — — Timer WEEKLY TIMER — —
Power-Airflow Diffuser — — 24-Hour ON/OFF TIMER
Wide-Angle Fins (Vertical Blades) NIGHT SET Mode
Vertical Auto-Swing (Up and Down) Worry Free
“Reliability &
Durability”
Auto-Restart (after Power Failure)
Horizontal Auto-Swing (Right and Left) — — Self-Diagnosis (Digital, LED) Display
3-D Airflow — — Wiring Error Check Function — —
COMFORT AIRFLOW Operation
Anti-Corrosion Treatment of Outdoor
Heat Exchanger
Comfort
Control
Auto Fan Speed Flexibility
Multi-Split / Split Type Compatible
Indoor Unit
——
Indoor Unit Quiet Operation
NIGHT QUIET Mode (Automatic) — — H/P, C/O Compatible Indoor Unit
Outdoor Unit Quiet Operation (Manual) — — Flexible Power Supply Correspondence — —
INTELLIGENT EYE Operation — — Chargeless
32.8 ft 32.8 ft
Quick Warming Function
(Preheating Operation)
— Either Side Drain (Right or Left)
Hot-Start Function — Power Selection — —
Automatic Defrosting —
Low Temperature Cooling Operation
(–15°C) (5°F)
Operation Automatic Operation —
Program Dry Function
°F/°C Changeover R/C Temperature
Display (factory setting : °F)
Fan Only Remote
Control
5-Room Centralized Controller (Option)
Lifestyle
Convenience
New POWERFUL Operation
(Non-Inverter)
——
Remote Control Adaptor
(Normal Open-Pulse Contact) (Option)
Inverter POWERFUL Operation
Remote Control Adaptor
(Normal Open Contact) (Option)
Priority-Room Setting — —
COOL / HEAT Mode Lock — — DIII-NET Compatible (Adaptor) (Option)
HOME LEAVE Operation — — Remote
Controller
Wireless
ECONO Operation Wired (Option)
Indoor Unit ON/OFF Button
Signal Receiving Sign
R/C with Back Light
Temperature Display — —
Note: : Holding Functions
— : No Functions