Forced Cooling Operation SiUS041111
222 Trial Operation and Field Settings
2. Forced Cooling Operation
Indoor Unit (09/12 class)
Indoor Unit (15/18/24 class)
Outdoor Unit (15/18/24 class only)
Item Forced Cooling
Conditions The forced cooling operation is allowed when both the following conditions are
met.
1) The outdoor unit is not abnormal and not in the 3-minute standby mode.
2) The outdoor unit is not operating.
Start The forced cooling operation starts when any of the following conditions is fulfilled.
1) Press the forced cooling operation ON/OFF button (SW1) on the indoor unit for
5 seconds.
2) Press the forced cooling operation ON/OFF switch (SW1) on the outdoor unit.
(15/18/24 class only)
Command
frequency
58 Hz: 09/12 class
30 Hz: 15/18/24 class
End The forced cooling operation ends when any of the following conditions is fulfilled.
1) The operation ends automatically after 15 minutes.
2) Press the forced cooling operation ON/OFF button (SW1) on the indoor unit
again.
3) Press the ON/OFF button on the remote controller.
4) Press the forced cooling operation ON/OFF switch (SW1) on the outdoor unit.
Others The protection functions are prior to all others in the forced cooling operation.
ON/OFF
(R14578)
ON/OFF button (SW1)
ON/OFF button (SW1)
(R14258)
1
2
3
Screwdriver
SW1
(R14259)

Table of Contents

Other manuals for Daikin FTXN24KVJU

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin FTXN24KVJU and is the answer not in the manual?

Daikin FTXN24KVJU Specifications

General IconGeneral
BrandDaikin
ModelFTXN24KVJU
CategoryAir Conditioner
LanguageEnglish

Related product manuals