SiUS041111 Outdoor Unit: 09/12 Class
Removal Procedure 167
3. Outdoor Unit: 09/12 Class
Note: The illustrations are for heat pump models as representative.
3.1 Removal of Outer Panels
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Step Procedure Points
1. Appearance features
Take care not to cut your finger
by the fins of the outdoor heat
exchanger.
2. Remove the panels.
When reassembling, make sure
to fit the 3 hooks.
1
Remove the screw of
the stop valve cover.
Pull down the stop
valve cover and remove
it.
(R11741)
(R14687)
(R14688)
Stop valve
cover
(R14689)
Hook