SiUS041111 Outdoor Unit: 09/12 Class
Removal Procedure 187
3.5 Removal of Four-Way Valve
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Step Procedure Points
1. Remove the peripheries. The cooling only model has no
four-way valve coil.
1
Remove the screw and
remove the four-way
valve coil.
2
Remove the terminal
cover.
3
Disconnect the
terminals of the
compressor.
4
Remove the overload
protector.
(R11799)
Four way valve coil
(R11797)
Terminal cover
(R14529)
U (red)
V (yellow) W (blue)
Overload
protector