EN
Installation Guide Danfoss Icon™ Master Controller 24 V
Er12 Actuator defective.
The defective actuator output is
ashing.
Replace actuator.
Er14 A Danfoss Icon Master Controller
cannot be included as (become)
a Slave Controller because one or
more room thermostats, repeaters
or Danfoss IconMaster Controller
24V have already been included.
This Danfoss Icon Master Controller 24V has to
be factory reset to become a Slave Controller. (See
description in chapter ”Reset or replace a Danfoss
Icon Master Controller).
Er16: This application requires a specic
actuator output to be available.
You have already assigned this output to a
room thermostat, or the output has not yet had
an actuator tted. Please remove output from
thermostat, it must be available to the application
chosen (or t actuator - if this was not yet done)
Er17: External PT1000 sensor not tted,
or defective.
Check sensor and replace if necessary.
Hydraulic balance
When using the Danfoss Icon Master Controller
24V with PWM+ regulation, the system will auto-
matically balance the circuits.
In heating systems with extreme dierences in cir-
cuit lengths, the automatic balancing might not be
adequate.
In these cases the Danfoss Icon Master Controller
24V can help you determine which circuits that are
struggling to get enough ow:
1. Press to select RUN mode.
2. Press an button to see the average duty cycle
in percentage for the selected circuit.
OK
When pressing the output button the average duty
cycle is shown in the display of the Danfoss Icon
Master Controller 24V.
The duty cycle is shown as the amount of time in
% that the actuator is open during active heating
periods and only when in heating mode as an av-
erage over time.
This feature can help determine if one or more
rooms have diculty receiving enough ow or ef-
fect to reach optimal comfort.
The room with the highest duty cycles is the one
that calls for the highest ow. If this room has prob-
lems reaching the desired room setpoint temper-
ature, the following steps can help give this room
more ow/heating capacity:
1. Increase the ow for the room with the high-
est duty cycle, using the pre-setting valve
on the manifold -> set to maximum ow on
pre-setting valves for this rooms outputs.
2. If the room with the highest duty cycle is al-
ready at maximum ow, instead reduce the
ow for the outputs that show the lowest duty
cycle (these do not need as much ow).
3. If none of the above is enough to reach the
desired room temperature, increase the total
ow, by setting a higher ow on the circula-
tion pump.
4. As a last resort increase the supply tempera-
ture into the system.
Note! By installing an Expansion Module in the
Danfoss Icon Master Controller 24V the system
will be able to automatically adjust the supply
temperature according to heat demand in the rooms.
VIMCG30F | 088N3678 | 11
© Danfoss | FEC | 2019.02

Table of Contents

Other manuals for Danfoss Icon

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss Icon and is the answer not in the manual?

Danfoss Icon Specifications

General IconGeneral
BrandDanfoss
ModelIcon
CategoryThermostat
LanguageEnglish

Related product manuals