Imaging Commands
7-10 PowerScan
®
7000 2D
IMGBOX Modifiers
D - Pixel Depth: Indicates the number of bits per pixel in the transmit-
ted image.
8D 8 bits per pixel, grayscale image
1D 1 bit per pixel, black and white image
F - File Format: Indicates the type of file format in which to save the
image.
0F KIM format (default)
1F TIFF binary
2F TIFF binary group 4, compressed
3F TIFF grayscale
4F Uncompressed Binary
5F Uncompressed grayscale
6F JPEG image
7F Outlined image
8F BMP format
H - Height of Signature Capture Area: In the example, the height of the
area to be captured is 1 inch, resulting in a value of H = 1/0.01 = 100.
The value for H is slightly larger, to accommodate some extra image cap-
ture area outside of the signature capture box.
K - Gamma Correction: Gamma measures the brightness of midtone
values produced by the image. You can brighten or darken an image
using gamma correction. A higher gamma correction yields an overall
brighter image. The lower the setting, the darker the image. A setting of
100 results in no adjustment to the image. (Default = 50K)
0K Gamma correction off

Table of Contents

Other manuals for Datalogic PowerScan 7000 2D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan 7000 2D and is the answer not in the manual?

Datalogic PowerScan 7000 2D Specifications

General IconGeneral
BrandDatalogic
ModelPowerScan 7000 2D
CategoryBarcode Reader
LanguageEnglish

Related product manuals