OCR Check Character
Product Reference Guide 8-11
dddddddc
To create this template, you would enable the OCR-A font. Scan the
Modulo 10 Check Character symbol. Then scan the Enter OCR Template
symbol, and scan the
d from the OCR Programming Chart seven times,
and scan the
c once. Scan Save OCR Template (page 8-17). This tem-
plate will let you read any combination of six digits with a correct check
character after. (If the check character is invalid, the imager will issue an
error beep.) For example, the following string could be scanned:
01234569
and the output would be: 0123456
OCR Modulo 10 Check Character
Scan this symbol to program the OCR template for a simple modulo 10
checksum of the digits 0 through 9.
OCR Modulo 36 Check Character
Scan this symbol to program the OCR template for a simple modulo 36
checksum of the digits 0 through 9 and the letters A through Z.
OCR Modulo 10 Check Character
OCR Modulo 36 Check Character

Table of Contents

Other manuals for Datalogic PowerScan 7000 2D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan 7000 2D and is the answer not in the manual?

Datalogic PowerScan 7000 2D Specifications

General IconGeneral
BrandDatalogic
ModelPowerScan 7000 2D
CategoryBarcode Reader
LanguageEnglish

Related product manuals