Chapter 8 Option CardsC2000
8-14
8-2 EMC-D42A -- Extension card for 4-point digital input/ 2-point digital input
I/O Extension
Card
Terminals Descriptions
COM
Common for Multi-function input terminals
Select SINK (NPN) / SOURCE (PNP) in J1 jumper / external power
supply
MI10–MI13
Refer to parameters 02-26–02-29 to program the multi-function
inputs MI10–MI13.
Internal power is applied from terminal E24: +24V
DC
±5% 200mA,
5W
External power +24V
DC
: max. voltage 30V
DC
, min. voltage 19V
DC
,
30W
ON: the activation current is 6.5mA
OFF: leakage current tolerance is 10μA
MO10–MO11
Multi-function output terminals (photocoupler)
The AC motor drive releases various monitor signals, such as drive
in operation, frequency attained and overload indication, via
transistor (open collector).
MO10
MO11
MXM
MXM
Common for multi-function output terminals MO10,
MO11(photocoupler)
Max 48V
DC
50mA
8-3 EMC-D611A -- Extension card for 6-point digital input (110V
AC
input voltage)
I/O Extension
Card
Terminals Descriptions
AC AC power Common for multi-function input terminal (Neutral)
MI10–MI15
Refer to Pr. 02-26
Pr. 02-31 for multi-function input selection
Input voltage: 100–130V
AC
Input frequency: 47–63Hz
Input impedance: 27Kohm
Terminal response time:
ON: 10ms
OFF: 20ms
8-4 EMC-R6AA -- Relay output extension card (6-point N.O. output contact)
Relay Extension
Card
Terminals Descriptions
RA10–RA15
RC10–RC15
Refer to Pr. 02-36– Pr. 02-41 for multi-function output selection
Resistive load:
3A (N.O.) / 250V
AC
5A (N.O.) / 30V
DC
Inductive load (COS 0.4)
1.2A (N.O.) / 250V
AC
2.0A (N.O.) / 30V
DC
It is used to output each monitor signal, such as drive is in
operation, frequency attained or overload indication.