EasyManuals Logo
Home>Delta>DC Drives>C2000 Series

Delta C2000 Series User Manual

Delta C2000 Series
936 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #761 background imageLoading...
Page #761 background image
Chapter 15 CANopen Overview C2000
15-34
15-6 CANopen LED Function
There are two CANopen flash signs: RUN and ERR.
RUN LED:
LED status Condition CANopen State
OFF OFF Initial
Blinking
Pre-Operation
Single flash
ON
OFF
單次閃爍
200
ms
200
ms
1000
ms
Stopped
ON ON Operation
ERR LED:
LED status Condition / Status
OFF No Error
Single
flash
One Message failure
ON
OFF
單次閃爍
200
ms
1000
ms
Double
flash
Guarding failure or heartbeat failure
ON
OFF
雙次閃爍
200
ms
200
ms
1000
ms
200
ms
Triple flash
SYNC failure
ON
OFF
雙次閃爍
200
ms
200
ms
200
ms
200
ms
1000
ms
200
ms
ON Bus off

Table of Contents

Other manuals for Delta C2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta C2000 Series and is the answer not in the manual?

Delta C2000 Series Specifications

General IconGeneral
BrandDelta
ModelC2000 Series
CategoryDC Drives
LanguageEnglish

Related product manuals