EasyManuals Logo
Home>Delta>DC Drives>C2000 Series

Delta C2000 Series User Manual

Delta C2000 Series
936 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #787 background imageLoading...
Page #787 background image
Chapter 16 PLC Function ApplicationsC2000
16-26
16-5 Various PLC device functions
Item Specifications Notes
Algorithmic control
method
Program stored internally, alternating
back-and-forth scanning method
Input/ output control
method
When it starts again after ending (after execution to
the END command), the input/ output has an
immediate refresh command
Algorithmic
processing speed
Basic commands (several μs);
Applications command (1 to
several tens of μs)
Programming
language
Command + ladder diagram
Program capacity 10000 steps
Input/ output terminal Input (X): 10, output (Y): 4
This number of contacts
constitutes C2000 input/ output
contacts; other devices have
different correspondences
Type Device Item Range Function
Relay bit
form
X External input relay
X0–X17, 16 points, octal
number
Total
32
points
Corresponds to external
input point
Y External output relay
Y0–Y17, 16 points, octal
number
Corresponds to external
output point
M
Auxiliary
Relay
General Use M0–M799, 800 points
Total
880
points
Contact can switch On/ Off
within the program
Special
purpose
M1000–M1079, 80 points
T Timer 100ms timer T0–T159, 160 points
Total
160
points
Timers referred to by the
TMR command; contact of
the T with the same
number will go On when
the time is reached
C Counter
16-bit counter,
general use
C0–C79, 80 points
Total
80
points
Counter referred to by the
CNT command; contact of
the C with the same
number will go On when
the count is reached
Register
word data
T Current timer value T0–T159, 160 points
The contact will be On
when the time is reached
C Current counter value C0–C79, 16-bit counter 80 points
The counter contact will
come On when the count is
reached
D
Data
Register
Used to
maintain
power Off
D0–D399, 400 points
Total
1400
points
Used as data storage
memory area
Special
purpose
D1000–D1199, 200 points
D2000–D2799, 800 points
Constant
K Decimal
Single-byte Setting Range: K-32,768–K32,767
Double-byte Setting Range: K-2,147,483,648–K2,147,483,647
H Hexadecimal
Single-byte Setting Range:H0000–HFFFF
Double-byte Setting Range: H00000000–HFFFFFFFF
Serial communications port (program
write/read)
RS-485/ keypad port
Input/output Built-in three analog inputs and two analog outputs
Function expansion module Optional
Accessories
EMC-D42A; EMC-R6AA; EMCD611A
Communication Expansion
Module
Optional
Accessories
EMC-COP01,(CANopen)

Table of Contents

Other manuals for Delta C2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta C2000 Series and is the answer not in the manual?

Delta C2000 Series Specifications

General IconGeneral
BrandDelta
ModelC2000 Series
CategoryDC Drives
LanguageEnglish

Related product manuals