Chapter 11 Summary of Parameter SettingsC2000
11-46
Pr. Parameter Name Setting Range Default
09-84
Communication card gateway address 1
(for MODBUS TCP)
0–65535 0
09-85
Communication card gateway address 2
for MODBUS TCP)
0–65535 0
09-86
Communication card gateway address 3
(for MODBUS TCP)
0–65535 0
09-87
Communication card gateway address 4
(for MODBUS TCP)
0–65535 0
09-88
Communication card password
(Low word) (for MODBUS TCP)
0–99 0
09-89
Communication card password
(High word) (for MODBUS TCP)
0–99 0
09-90
Reset communication card
(for MODBUS TCP)
0: Disable
1: Reset, return to default
0
09-91
Additional settings for the communication
card (for MODBUS TCP)
bit0: Enable IP filter
bit 1: Enable internet parameters (1 bit).
When IP address is set, this bit is
enabled. After updating the
communication card parameters, this bit
changes to disabled.
bit 2: Enable login password (1 bit).
When you enter the login password, this
bit is enabled. After updating the
communication card parameters, this bit
changes to disabled.
0
09-92
Communication card status
(for MODBUS TCP)
bit0: Enable password
When the communication card is set
with a password, this bit is enabled.
When the password is cleared, this bit is
disabled.
0