When the temperature exceeds the setting level, an oH3 error occurs to the drive. Reset
conditions: when the temperature is below the trigger level -5ºC, the oH3 error is cleared.
When the KTY is not connected, or the KTY is burned, the calculated temperature is beyond
-40–150ºC, the temperature is displayed as its lower limit (-40ºC) or upper limit (150ºC) without
additional error information. At this time, the drive still trips up the oH3 error, check if the
installation is correct.
When the temperature detection warning occurs to the KTY-84, select the action according to Pr.
06-29.
y = 79.717x
-
156.64
-100
0
100
200
1.50 2.00 2.50 3.00 3.50 4.00
T
(°C)
A
nalog voltage (V)
C2000 / KTY84-130 Temperature and voltage diagram
C2000
Linear (C2000)