Chapter 12 Description of Parameter SettingsC2000
12.2-00-2
FOC sensorless control diagram
Adjustment procedure
1. Parameter reset to default, Pr.00-02 = 10 or 9
(To avoid other parameters that are not related affecting the motor controlling)
2. Set up motor parameters according to the nameplate on the motor
Pr. 01-01 Output Frequency of Motor 1
Pr. 01-02 Output Voltage of Motor 1
Pr. 05-01 Full-load Current for Induction Motor 1
Pr. 05-02 Rated Power for Induction Motor 1
Pr. 05-03 Rated Speed for Induction Motor 1
Pr. 05-04 Number of Poles for Induction Motor 1