109
EN
Troubleshooting
10. Troubleshooting
LED Indicator (Green/Red)
Green - ON: Operating
Blinking: Countdown
Red - ON: Error/Fault
Blinking: Warning
Figure 10.6.: LED Indicator
Message Red LED
on
Red LED
blinks
Solution
Errors
AC Freq High X Check grid frequency on the inverter
terminal
Check the country setting
AC Freq Low X Check grid frequency on the inverter
terminal
Check the country setting
Grid Quality X Check the harmonics of the grid
voltage
Grid connection of the inverter may
need to be further away from a non-
linear load.