INSTALLATION INSTRUCTIONS
EPT031055 Issue 2 September 2017 2-41
PCB Connector Type: IEC 60130-9 Type 7 way male,
Mating Cable Connector (IP67 Types): Lumberg: 0322 07
Install the X29 / X68 cable for all systems (with and without shutter) and
connect the guard door etc. to X69.
A standard X29 cable might be used for to connect the X69 but then one
should take care to replace the X29 label by an X69 label in order to avoid
confusion!
Furthermore, if the X29 cable is used for the X69 connection and the system
is equipped with a shutter the documentation of the X29 cable is no more
valid in respect to some of the lead functionality labels, which must be
changed according to the X69 pin description see below
This connector is mostly compatible to the standard X29, but there are
some differences; the most significant are:
• X69 is not floating but related to case GND / PE
• The only possible configuration of the safety guard is the connection of
2 electrically isolated safety switches
• GND moved to the former X29 READY pin
• EXT_LSTART_IN must be used as this is the ONLY way to enable the
shutter