Installation and Operation Manual
E2K-405-0218 Rev. 2
February 2018
51
Section 5: Customizing Actuator Settings
Customizing Actuator Settings
Figure 5-8 Set Valve Travel Limits
Normal Operation Mode - Set Limits with Handwheel Operation
Figure 5-7 Normal Operation Mode - Set Limits With Electrical Operation
Go to
Figure 5-6
Go to
Figure 5-4
YES YES YES
YES
Accept Valve
Close Limit?
Accept Valve
Open Limit?
Declutch actuator.
Rotate handwheel to
“CLOSE” direction.
When done, select “STOP”.
Save the Valve
Travel Limits
NO
NO
NO
BACK NEXT
NO
Select Local
and
Close Valve
Select Local
and
Open Valve
LOCAL LOCAL
Close Valve
Then
Select Stop
Open Valve
Then
Select Stop
BACK
SET VALVE
TRAVEL LIMITS?
SAVE LIMITS?
STOPSTOP
Declutch actuator.
Rotate handwheel to
“OPEN” direction.
When done, select “STOP”.
NO
or
NEXT