Installation and Operation Manual
E2K-405-0218 Rev. 2
February 2018
73
Section 6: Troubleshooting
Troubleshooting
6.2 Display Diagnostics
Displaying diagnostics retrieves historical data that is stored in the actuator’s memory.
This aids in troubleshooting.
1. At the “DISPLAY DIAGNOSTICS?” prompt, answer “YES.
2. Use the selector knob (NEXT/BACK) to review the settings. See Figure 6-1.
NOTE:
When the “SET LIMITS BEFORE OPERATING” alarm is displayed, no other alarms will be
displayed until the limits are set.
Figure 6-1 Display Diagnostics
YES
BACK
Figure 6-1Display
Diagnostic
Display
Alarm
Log?
YES
BACK
NEXT
DISPLAY
HARDWARE
DIANOSTICS?
EXIT?
Go to
Figure 6-2
Go to next display.
See Figure 5-1
NO
OR
NEXT
NO
NO
NO
NO
NO
NO
YES
Display
Torque
Profile?
Go to
Figure 6-3
YES
Display
Torque
Archive?
Go to
Figure 6.2.3
YES
Display
Operate
Log?
Go to
Figure 6-4
YES
Display
Operate
Archive?
Go to
Figure 6-5
YES
Display
Hardware
State?
Go to
Flowchart 6-6

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Bettis 500 and is the answer not in the manual?

Emerson Bettis 500 Specifications

General IconGeneral
BrandEmerson
ModelBettis 500
CategoryController
LanguageEnglish

Related product manuals