6.2.3 Display Torque Archive
Torque archive is displayed like Torque Prole. Torque archive is the data stored at
the time commanded by the user in the “CHANGE SETTINGS” mode. See Section
5.5.2, Valve Control Setup and Figure 5-6.
1. At the “DISPLAY TORQUE ARCHIVE?” prompt, answer “YES.”
2. See Section 6.2.2, Display Torque Profile, and Figure 6-3.
6.2.4 Display Operation Log
Operation log aids in troubleshooting because it contains the operation data
accumulated since the operation log was reset. See Figure 6-4.
1. At the “DISPLAY OPERATE LOG?” prompt, answer “YES.”
2. Use the control knob (YES) to review the operate log.
Motor starts value is the number of times the motor has been started. The strokes
value displayed is the number of full strokes from limit to limit. Stroke time can be
measured as follows:
1. Reset operation log.
2. Stroke the valve. Stroke time is equal to the motor run time.
Motor run time is the total motor operational time.
To reset operation log:
1. Enter “Change Settings” mode.
2. Select “VALVE CONTROL SETUP?”
See Section 5.5.2, Valve Control Setup
Figure 6-4 Display Operation Log