102 Mentor MP User Guide
www.controltechniques.com Issue: 3
Figure 11-3 Menu 3 logic diagram
* If Pr 5.28 (Field weakening compensation disable) is set to ‘OFF (0)’ a multiplication factor is applied to the speed loop gains when the flux is below
100%.
3.35
Drive encoder marker
mode
3.36
Drive encoder
supply voltage
3.38
Drive encoder type
3.39
Drive encoder
termination select
Encoder interface
15.03
Speed feedback
from option
module in slot 1
16.03
17.03
Speed feedback
from option
module in slot 2
Speed feedback
from option
module in slot 3
Feedback from the
option modules set-up
in Menus 15, 16 and 17
3.27
Drive encoder
speed feedback
Speed feedback
selector
3.43
Maximum drive
encoder
reference (rpm)
3.05
Speed feedback
3.02
3.31
Drive encoder marker
position reset disable
3.32
Drive encoder marker
flag
3.33
Drive encoder turns
3.34
Drive encoder lines
per revolution
3.47
Re-initialise position
feedback
Position feedback
initialised
3.49
Full motor object
electronic nameplate
transfer
3.54
Encoder direction
3.40
Drive encoder error
detection level
3.42
Drive encoder filter
3.48
3.52
Tacho speed
5.04
Estimated
speed
3.51
Tachometer
voltage rating
3.53
Tachometer input
mode
Drive
tachometer
input
3.45
3.44
Any unprotected
variable parameter
??.??
??.??
3.46
Drive encoder
reference
Drive encoder
reference scaling
Drive encoder
reference
destination
Speed feedback
percentage
3.58
3.28
3.29
Drive encoder
revolution counter
Drive encoder
position
Zero speed
3.06
‘At speed’
lower limit
3.07
‘At speed’
upper limit
3.08
Overspeed
threshold
3.09
Absolute ‘at
speed’ detect
Speed detector threshold
levels
Zero speed
Speed detector flags
10.03
Running at
or below
minimum
speed
10.04
Below set
speed
10.05
At speed
10.06
Above set
speed
10.07
0.XX
0.XX
Key
Read-write
(RW)
parameter
Read-only (RO)
parameter
Input
terminals
Output
terminals
The parameters are all shown at their default settings
+
Final speed
reference
+
3.23
1.11
Hard speed
reference
selector
Reference
enabled
indicator
3.22
Hard speed
reference
3.21
Damping factor
Speed controller set-up
3.16
Speed controller gain
select
3.17
Speed controller
set-up method
3.18
Motor and load
inertia
3.20
Bandwidth
3.03
Speed
error
Speed loop gains*
3.04
Speed
controller
output
3.10
3.11
(Ki1)
(Kp1)
3.13
3.14
(Ki2)
(Kp2)
+
_
+
_
3.01
Menu 2
x-1
Speed controller
differential
feedback gains
(Kd1)
3.15
3.12
(Kd2)
3.55
Select estimated
speed on feedback
loss
3.56
Speed feedback
loss window
3.57
Estimated speed
has been
automatically
selected
3.26
5.86
Speed error
invert
Held at 0 when in
direct firing angle