Safety
Information
Product
information
Mechanical
Installation
Electrical
installation
Getting
started
Basic
parameters
Running the
motor
Optimization
SMARTCARD
operation
Onboard
PLC
Advanced
parameters
Technical
data
Diagnostics
UL
information
Mentor MP User Guide 59
Issue: 3 www.controltechniques.com
The OR of Pr 23.03 to Pr 23.09. To be used by the MP-Keypad.
When this parameter is set to 1 the associated pre-defined sub block is
accessible. When this parameter is 0 the associated pre-defined block is
bypassed.
5.4 Pre-defined sub blocks
Set-up
Diagnostic
Trips
Speed loop
Serial interface
23.02 OR of pre-defined sub block enables
RO NC PT BU
Ú
0 to 127
Ö
0
Parameter Value
23.03 1
23.04 2
23.05 4
23.06 8
23.07 16
23.08 32
23.09 64
23.03 - 23.09 Pre-defined sub block enable
RW Bit US BU
Ú
0 to1
Ö
1
Parameter Description Display
23.03 Set up SEt UP
23.04 Diagnostic diAGnoS
23.05 Trips triPS
23.06 Speed loop SP LOOP
23.07 Serial interface SintEr
23.08 Speed feedback Fb SP
23.09 IO InPut
Menu 0 Parameter Description Display
0.01 to
0.20
Configured by Pr 22.01 to
Pr 22.20
Menu 0 Parameter Description Display
0.21 1.00 Parameter 0 SE00
0.22 1.07 Minimum reference clamp SE01
0.23 1.06 Maximum reference clamp SE02
0.24 2.11 Acceleration rate SE03
0.25 2.21 Deceleration rate SE04
0.26 1.14 Reference selector SE05
0.27 5.09 Armature rated voltage SE06
0.28 5.07 Motor rated current SE07
0.29 5.08 Base speed SE08
0.30 11.42 Parameter copying SE09
0.31 5.70 Rated field current SE10
0.32 5.73 Rated field voltage SE11
0.33 5.77 Enable field control SE12
0.34 5.12 Autotune SE13
0.35 11.44 Security status SE14
Menu 0 Parameter Description Display
0.36 1.01 Speed reference selected di01
0.37 1.03 Pre-ramp reference di02
0.38 2.01 Post ramp reference di03
0.39 3.01 Final speed reference di04
0.40 3.02 Speed feedback di05
0.41 3.04 Speed controller output di06
0.42 4.03 Torque demand di07
0.43 4.01 Current magnitude di08
0.44 5.56 Field current feedback di09
0.45 5.02 Armature voltage di10
0.46 1.11 Reference enabled indicator di11
0.47 1.12 Reverse selected indicator di12
0.48 1.13 Jog selected indicator di13
0.49 11.29 Software version di14
0.50 0.00 Spare
Menu 0 Parameter Description Display
0.51 10.20 Trip 0 tr01
0.52 10.21 Trip 1 tr02
0.53 10.22 Trip 2 tr03
0.54 10.23 Trip 3 tr04
0.55 10.24 Trip 4 tr05
0.56 10.25 Trip 5 tr06
0.57 10.26 Trip 6 tr07
0.58 10.27 Trip 7 tr08
0.59 10.28 Trip 8 tr09
0.60 10.29 Trip 9 tr10
Menu 0 Parameter Description Display
0.61 3.10
Speed controller
proportional gain
SP01
0.62 3.11
Speed controller integral gain
SP02
0.63 3.12
Speed controller differential
feedback gain
SP03
0.64 0.00 Spare
0.65 0.00 Spare
Menu 0 Parameter Description Display
0.66 11.25 Baud rate Si01
0.67 11.23 Serial address Si02
0.68 0.00 Spare
0.69 0.00 Spare
0.70 0.00 Spare