Safety
Information
Product
information
Mechanical
Installation
Electrical
installation
Getting
started
Basic
parameters
Running the
motor
Optimization
SMARTCARD
operation
Onboard
PLC
Advanced
parameters
Technical
data
Diagnostics
UL
information
Mentor MP User Guide 121
Issue: 3 www.controltechniques.com
Figure 11-13 Menu 9 logic diagram: Motorized potentiometer and binary sum
9.30
Binary-sum
logic twos
9.29
Binary-sum
logic ones (LSB)
9.31
Binary-sum
logic fours (MSB)
9.32
Binary-sum
logic output
value
??.??
Any
unprotected
bit
parameter
??.??
9.33
Binary-sum
logic
destination
parameter
Σ
9.24
Motorized
pot.
output scale
9.25
Motorized
pot.
destination
parameter
9.23
Motorized
pot. rate
??.??
Any
unprotected
variable
parameter
??.??
9.27
Motorized pot.
down
9.26
Motorized pot.
up
M
9.03
Motorized pot.
output
indicator
9.22
Motorized
pot. bipolar
select
9.21
9.28
Motorized pot.
reset to zero
Motorized pot.
mode
+
+
9.34
Binary-sum
offset
0.XX
0.XX
Key
Read-write
(RW)
parameter
Read-only (RO)
parameter
Input
terminals
Output
terminals
The parameters are all shown at their default settings
Function disabled if set
to a non valid destination
Function disabled if set
to a non valid destination

Table of Contents