Maintenance 11. Lithium Battery and Boards
148 LS Rev.10
11.1 Replacing the Battery Unit (Lithium Battery)
Maintenance: 3.3 Connector Plate.
Take out the battery plate from the Base.
Battery plate mounting screw: 1 - M3×5
Be careful not to disconnect the battery connector.
you disconnect all the current batteries before connecting the new battery, the robot
the home position data and the calibration must be executed again. The
battery units are exchanged according to the following procedures.
wire tie binding the lithium batteries to the battery plate.
Bind new batteries to the battery plate with a new wire tie.
Mount the battery plate to the cable support.
Battery plate mounting screw: 1 - M3×5
Disconnect one connector of the old three batteries and connect a new one.
Disconnect the other old batteries connector and connect new ones.
Mount the Connector Plate.
Maintenance: 3.3 Connector Plate.
Check if the manipulator moves to points correctly in correct orientation.
To do so, select some points already registered and move the manipulator to the
points.
manipulator does not move to the points correctly, execute
the calibration of all
joints and axes.
Maintenance: 13. Calibration.