Maintenance 3. Covers
76 LS Rev.10
3.3 Connector Plate
CAUTION
■
Do not remove the connector plate
. Removing the connector plate
forcibly may result in damage to the cables, disconnection, and/or contact failure.
Damaged cables, disconnection, or
contact failure is extremely hazardous and
may result in electric shock and/or improper function of the robot system.
When installing the connector plate, b
e careful not to allow the cables to interfere
with the plate mounting and d
o not bend these cables forcibly to push them into
Unnecessary strain on cables may result in damage to the cables, disconnection,
and/or contact failure. Damaged cables, disconnection, or contact failure is
extremely hazardous and may result i
n electric shock and/or improper function of
routing the cables, observe the cable locations
after removing the
connector plate
. Be sure to place the cables back to their original locations.
Unscrew the Connector Plate mounting
bolts and remove the plate.
The fittings position and size of the
Connector Plate are different for LS6
and LS3.
The screws’ position and size are
common. The figure is LS3.
When mounting the Connector Plate, be careful of the following.
Prevent the air tube from bending sharply inside the
manipulator. Also, do not block the air flow.
If there is a kink in the air tube, air flow is blocked while
the manipulator is operating and may cause a trouble.
Put the air tube along the left side wall as shown in the
picture.