9
10
E1SL 14 532258 04 - Rev. B
L0...L1...L2
5 s
SW1
SETUP/RESET
L0
3.4
5 s
+
F
--
Translation of the original instructions
ENGLISH
7.2 SETUP
The board acquires the movement space of the leaves via the SETUP.
WHEN IS SETUP NECESSARY?
- when the automation is first put into operation or after replac-
ing the board
- after a change in the model of the automation, or the direction of
rotation of the motor, or the DM KIT has been enabled/disabled
- following any travel variation
- following a change in the number of leaves or the passage open-
ing for the SF1400
- after a reset to factory settings
- when the display indicates error
39
Impediments to SETUP The following are reasons for the SETUP proce-
dure NOT being carried out or being interrupted (error
15):
- emergency inputs active
- MANUAL mode selected
- NIGHT-TIME operating mode
- the automation is operating on the battery, as there is no mains
power.
Activation of the safeties does not prevent
SETUP from being per-
formed
PERFORM
SETUP
!
The inputs configured as safeties are ignored during SETUP. To prevent
any hindrance to motion, keep at a distance and prevent anyone from
going near the system.
1. Make sure that there is nothing that can prevent the
SETUP pro-
cedure from being carried out and that the correct automation
model has been set.
2. Bring the leaf to its halfway position.
3. Start the
SETUP procedure:
- from board: press and hold the SW1 button for approximately 5 s, until
LO
appears on the display
- from SDK EVO: /
PROGRAMMING/INSTALLATION/START SETUP OK
4. The display shows the phases of the SETUP (L0…L2) and the
status of the automation when it has been completed.
If at the start of the
SETUP procedure, the automation OPENS instead
of CLOSING, reverse the direction of rotation of the motor:
- from board Basic programming:
rM
- from SDK EVO: /PROGRAMMING/INSTALLATION/MOTOR ROTATION select
STANDARD or NON STANDARD
SETUP
from board
LO start SETUP
L1 close the automation
L2 open the automation
Restoring factory settings
within 4 s of switching on
7.3 RESTORING FACTORY SETTINGS
The procedure:
- deletes the
SETUP data, the board LOG files and any TIMER
programming
- restores all the programming defaults, including the model of
the automation
- resets the cycle counters
- causes the time and date to be lost
- restores the default password (0000)
1. Turn off the mains power supply and disconnect the emergency
battery (if present), then turn the mains power back on.
2. Within the first 4 s after switching on (while the display is show-
ing the FW version), press the
F buttons simultaneously for
about 5 s
- The display indicates
--
3. Release the buttons: the display will indicate the status of the
automation.
After restoring the factory settings, carry out the set-up procedure
again.
To restore programming defaults ONLY:
- from board Basic programming:
dF select Y
- from SDK EVO: /PROGRAMMING/MISCELLANEUS/CONFIG. DEFAULT select
OK
if NO appears, select OK the following question appears:
…
DO YOU WANT TO LOAD DEFAULT CONFIG ? select OK or ESC