E1SL 18 532258 04 - Rev. B
Translation of the original instructions
ENGLISH
7 ADVANCED programming
ADVANCED Function Default: A1000 A1400 AIR RKE 1400 SF1400 GBF1500
P1
INPUT S1 configuration (see options C1)
20 20 20 20 20
1F
INPUT S1 TEST Displayed only if the input is configured as safety (P1 = 20 or 21 or 23)
Y = TEST enabled
no = TEST not enabled
YY YYy
P2
INPUT S2 configuration (see options C1)
20 20 20 20 20
2F
INPUT S2 TEST Displayed only if the input is configured as Safety (P2 = 20 or 21 or 23)
Y = TEST enabled
no = TEST not enabled
YY YYy
Ot
OPERATION OF SAFETIES IN OPENING
1 = STOP (stops the opening)
2 = Low Energy (slow movement)
22 222
bP
BUTTON PHOTOCELLS The TEST is NOT available for these photocells.
no = no photocell
1 = 1 pair of photocells
2 = 2 pairs of photocells
no no no no no
E1
INPUT E1 configuration (see options C1)
no no no no no
1F
INPUT E1 TEST Displayed only if the input is configured as Safety (E1 = 20 or 21 or 23).
Y
= TEST enabled
no = TEST not enabled
no no no no no
E2
INPUT E2 configuration (see options C1)
no no no no no
2F
INPUT E2 TEST Displayed only if the input is configured as Safety (E2 = 20 or 21 or 23)
Y = TEST enabled
no = TEST not enabled
no no no no no
bA
BATTERY KIT Operation of the emergency battery NOT in NIGHT-TIME mode.
no = not enabled
1 = OPENS immediately
2 = CLOSES immediately
3 = with flat battery last movement OPENING
4 = with discharged battery last movement CLOSING
no no no no no
bn
NIGHT BATTERY KIT Operation of the emergency battery in NIGHT-TIME operating mode. Displayed only if
the Battery Kit is enabled (
bA other than no). (see options bA)
44 444
EL
MOTOR BLOCK XB LOCK / XM LOCK XM LOCK options not displayed for A1000 (CF= 1)
no no no no no
no = not enabled
1 = XB LOCK closed in NIGHT-TIME mode
2 = XB LOCK closed in ENTRY ONLY, EXIT ONLY, NIGHT-
TIME mode
3 = XB LOCK closed in NIGHT-TIME mode and with
leaves open
4 = XB LOCK closed in NIGHT-TIME mode and with
leaves closed
5 = XB LOCK closed at the end of each movement
6 = XM LOCK closed in NIGHT-TIME mode
7 = XM LOCK closed in ENTRY ONLY, EXIT ONLY, NIGHT-
TIME mode
8 = XM LOCK closed in NIGHT-TIME mode and with
leaves open
9 = XM LOCK closed in NIGHT-TIME mode and with
leaves closed
10 = XM LOCK closed at the end of each movement
SU
MONITORING of XB LOCK / XM LOCK
no = not enabled
Y = enabled
no no no no no
dM
DOUBLE MOTOR KIT ACTIVATION
no = second motor kit not enabled
Y = second motor kit enabled - NOT displayed for SF1400 (CF= 4) or for GBF1500 (CF= 5)
-nonono-
nd
NIGHT-TIME MODE DELAY
0 … 90 s Adjustment step = 1 s
10 10 10 10 10